To repair the lockup unit of the A8LF1, A8LF2 torque converters, we recommend to use the TCRT 01.001 device.
To repair one torque converter, 2 FHK05 friction plates and 2 FHK06 friction plates are required.
Inner dia. (top of teeth)
115,4 mm / 4,543 inch
Inner dia. (bottom of teeth)
128,3 mm / 5,051 inch
Thickness
2,75 mm / 0,108 inch
Teeth count
24
Linings Count
One-sided
Teeth type
Internal
Linings Material
F1 (Fabor)
Linings Type
Segmented
Outer dia.
205,4 mm / 8,087 inch